Use a thermostat with all lube oil heaters to protect the oil from overheating. Lube oil heaters must always be installed in the sump with the entire heater submerged below the oil level at all times.
Lube Oil Heater (Weathertight)
د.إ0.000
Temperature Range | Code | |
ON | OFF | |
60°F (16C) | 80°F (27C) | 6 |
80°F (27C) | 100°F(38C) | 8 |
100°F(38C) | 120°F (49C) | 10 |
Power (Heater) | 50 Watts, 75 Watts, 125 Watts, 150 Watts, 225 Watts, 300 Watts, 450 Watts, 500 Watts |
---|---|
Oil Heater | |
Product Type | Genset |
QR Code

Related Products
- desktop-columns-3 tablet-columns-2 mobile-columns-1
-
CL Model (Watertight)
د.إ0.000Availability: In stockOut of stock
Pressure switch or relay for automatic operation
Universal mounting for varied mounting configuration
100° to 120°F fixed thermostats
On/Off switch for manual control
Watertight components rated NEMA 12
Viton mechanical seal pumps for extended seal life and temperatures to 350°F
External motor protective switch reset button -
Battery Wraps
د.إ0.000Availability: In stockOut of stock
Prolong the life of your battery with HOTSTART thermal battery wraps with or without thermostat.
• Durable, fire-retardant vinyl cover that resists oils and acids.
• All standard battery pads and battery wraps come with 6’ (1.8m) grounded cord and plug.
• Fast, easy installation.
• Boosts battery cranking power as much as 75%. -
SB Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)Adjustable 90° – 130°F (32°C – 54°C)
-
OSX Model
د.إ0.000Availability: In stockOut of stock
Heating Fluid: Oil
Heat Power: 1.5, 2.5 kW
Voltage Range: 240V/60Hz/1ph, 480V/60Hz/3ph (Contact TCT for other voltage requirements)
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 105°F (40°C)
High-Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High-Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.6 gal (2.2L)
Pump Power: 1, 2Hp (0.75, 1.5 kW) -
SL Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)
Adjustable 90° – 130°F (32°C – 54°C)
-
CB Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
- Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)
-
CLM Model
د.إ0.000Availability: In stockOut of stock
-
Heating Fluid: Engine coolant (50% glycol/50% water
Power: 27-36kW
Rated Voltage: 400V/50Hz/3ph, 440V/60Hz/3ph, 690V/50&60Hz/3ph
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 120°F (50°C)
High Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.9 gal (3.5L)
Pump Power: 0.75Hp (0.55kW)
-
-
EE Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C
Adjustable 90° – 130° (32°C – 54°C)
-
DLV System
د.إ0.000Availability: In stockOut of stock
Specification:
Heating Fluid: Coolant and Oil
Coolant Heat Power: 18 – 30 kW
Oil Heat Power: 6 – 12 kW
Rated Voltage: 208, 240, 480, 575 V (3Ø 60 Hz)
220, 380, 400, 415 V (3Ø 50 Hz)
Temp Controller, coolant: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 122 °F (50 °C)
Temp Controller, oil: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 104 °F (40 °C)
High-Limit Temperature Protection
Main Control Box Ingress Protection: NEMA 4 IP66
Coolant Motor Ingress Protection: IP55
Oil Motor Ingress Protection: IP55
Meets Vibration Specification IEC 60068-2-64
Meets Shock Specification IEC 60068-2-27